Services

Eight pillars. One technical file. Every statement traceable.

Regulatory work is one file viewed from eight angles. These pillars are not a menu of unrelated services; each one feeds and is fed by the others, and every page says which. Start with the flagship if your question is biological safety; start anywhere else and you will be shown how it connects.

Flagship 06 Biological evaluation, toxicological risk assessment and E&L A laboratory has proposed a full battery; a reviewer has asked for a toxicological risk assessment; a material changed and nobody knows what that means for the file. The answer in every case starts with endpoint selection under ISO 10993-1:2025 and ends with a document a toxicologist on the other side can follow line by line. Direct, flagship — delivered by the consultant; laboratory testing coordinated with named laboratories · First deliverable: Biological evaluation plan and TRA scope Discuss your biological evaluation →

How the pillars connect

Risk management sits at the centre: it feeds the electrical-safety test plan, the software hazard analysis, the biological evaluation's endpoint rationale and the post-market trend thresholds, and it is fed back by every one of them. Technical documentation is where all eight meet, because the technical file is the only place a reviewer sees them together. Regulatory strategy decides the order in which the rest is done, and for which markets. Quality management decides whether any of it can be repeated.

That is why each pillar page ends with a "How this connects" block rather than an unrelated list of other services. Choosing where to start is itself a regulatory decision; the scoping call exists to make it.

What "Direct", "Coordinated" and "Scoped per engagement" mean

Every service component carries one of three capability designations, set out in full on the scope and limitations page. Direct means the consultant delivers the full scope. Coordinated means Authentcare plans, briefs and reviews, and a named partner executes: a laboratory tests, a sterilisation contractor validates, a specialist firm penetration-tests. Scoped per engagement means the service is offered with a separately named qualified collaborator — a clinical specialist for clinical evaluation, an IVD scientist for performance evaluation — and the scope names them. No page on this site describes a capability that does not carry one of these designations.

Coordinated with specialist partners

Planning, documentation and coordination only. Execution sits with validation laboratories, sterilisation contractors, clinical collaborators or the manufacturer, named per project.

Coordinated sub-offers and the pillar each belongs to
Sub-offerParent pillarWhat Authentcare doesCurrent editions cited
Sterilisation validation planning02 QMSDefine the validation strategy, review protocols and reports, integrate into the medical device fileISO 11135:2014+A1:2018; ISO 11137-1:2025, -2:2013, -3:2017, ISO/TS 11137-4:2020; ISO 17665:2024
Packaging and shelf-life05 Technical documentationDefine the packaging validation plan, review ISO 11607 evidence, link to labelling and transport simulationISO 11607-1:2019+A1:2023; ISO 11607-2:2019+A1:2023
Microbiology and bioburden06 Biological evaluationScope bioburden, sterility and endotoxin requirements; coordinate laboratory workISO 11737-1:2018+A1:2021; ISO 11737-2:2019; ISO 11737-3:2023
Cleanroom qualification02 QMSDefine the classification and monitoring planISO 14644-1:2015; ISO 14644-2:2015
Reprocessing of reusable devices05 Technical documentationDefine reprocessing instructions and the validation evidence requiredISO 17664-1:2021; ISO 17664-2:2021
Usability engineering file07 Software, SaMDPlan and document the usability engineering process; coordinate formative and summative studiesIEC 62366-1:2015+A1:2020; IEC 60601-1-6 where applicable; current FDA human factors guidance
Clinical investigation and IVD performance study planning06 Clinical and IVD evaluationProtocol-level regulatory input; ethics and authority submission coordination, with a named clinical or IVD collaboratorISO 14155:2026; ISO 20916:2019; MDR Chapter VI; IVDR Chapter VI
Product environmental compliance03 Product complianceApplicability assessment and declaration supportRoHS Directive 2011/65/EU as amended; REACH Regulation (EC) 1907/2006; WEEE Directive 2012/19/EU

Not sure which pillar your problem sits in?

Most engagements start in one pillar and touch three. A scoping call places it.