06 Service · Flagship

Biological evaluation, toxicological risk assessment and E&L

A laboratory has proposed a full battery; a reviewer has asked for a toxicological risk assessment; a material changed and nobody knows what that means for the file. The answer in every case starts with endpoint selection under ISO 10993-1:2025 and ends with a document a toxicologist on the other side can follow line by line.

Capability
Direct, flagship — delivered by the consultant; laboratory testing coordinated with named laboratories
First deliverable
Biological evaluation plan and TRA scope
Typical turnaround
10 working days for the plan; 20 to 30 for the TRA

The situation

You are here for one of a small number of reasons. A laboratory has quoted a battery of tests and you suspect you do not need all of it. A notified-body or FDA reviewer has asked for a toxicological risk assessment, or has rejected the one you have. A supplier has changed a material, a colourant or a sterilisation process, and nobody can say which parts of the biological evaluation that invalidates. Or you are building the file for the first time and want it done once.

In each case the work starts in the same place: the device's nature and duration of contact under ISO 10993-1:2025, the materials and processes that make it, and the question of which biological endpoints that combination requires you to address. Only after that question is answered does anyone talk about testing.

What goes wrong when this is handled late

Testing bought before the evaluation is planned is the most common and most expensive error. A battery run on a device that was never categorised correctly produces reports that answer the wrong questions, and a reviewer notices. Tests run without chemical characterisation leave the toxicological endpoints unaddressed no matter how many biological assays were passed. Evaluations written as a list of passed tests, without the risk-management reasoning the 2025 edition now requires explicitly, come back with deficiency letters that take longer to answer than the original work would have taken to do properly.

The second error is treating the biological evaluation as a one-time document. Every material change, every new supplier declaration and every process change is a question for the evaluation, and a file that cannot show the question was asked is a file with a gap.

What Authentcare does

Assess. Categorise the device under ISO 10993-1:2025 by nature and cumulative duration of contact, including reasonably foreseeable misuse. Review the materials, formulation, processing aids, sterilisation and packaging for what they contribute. Review the chemical characterisation and test data you already hold. Identify, endpoint by endpoint, what is addressed and what is not.

Develop. Write the biological evaluation plan with the rationale for every endpoint decision. Design the extractables and leachables study where one is needed: extraction conditions that reflect clinical use, the analytical evaluation threshold derived and justified, and a brief the laboratory can quote against without guessing. Write the toxicological risk assessment when the characterisation data arrives. Consolidate everything into the biological evaluation report, and write the change assessment when something changes later.

Coordinate. Brief the laboratory, answer its questions, review the report on return against the brief and against the standard, and raise and close the gaps. Explain the evaluation to a reviewer in a structured dialogue or a deficiency response.

The illustration below is the endpoint logic abstracted from Authentcare's own plan structure. Most endpoints end in the upper box; the lower box is short, and every entry in it has a written reason.

Endpoint logic: contact and duration lead to endpoint categories, then to data held or a justified test From contact and duration to a justified test list Abstracted from Authentcare's biological evaluation plan structure. Not a reproduction of any standard's table. Nature of contactsurface · external · implant Cumulative durationlimited · prolonged · long-term Materials and processingformulation, sterilisation, residues Endpoints to address Cytotoxicity Sensitisation Irritation Systemic toxicity Material-mediated pyrogenicity Genotoxicity Implantation … as the categorisation requires Addressed by data heldchemical characterisation,toxicological risk assessment,prior testing, literature Test still justifiedrationale written per endpoint,laboratory briefed,report reviewed on return Most endpoints end in the upper box. The lower box is short, and every entry in it has a written reason.
From contact and duration to a justified test list. Not a reproduction of any standard's table.

The toxicological risk assessment

The TRA is where this practice is deepest, and it is where files most often fail. A good TRA under ISO 10993-17:2023 takes each compound the chemical characterisation identified, finds or derives a tolerable intake from the toxicological literature with the uncertainty factors stated, estimates the patient's exposure from the extraction data and the clinical use, and compares the two as a margin of safety, with the conclusion and its confidence written plainly. Where the literature is thin, the assessment says so and says what was done about it, rather than borrowing a value from an unrelated context and hoping no one checks.

The TRA is offered as a fixed-scope deliverable in two tiers by compound count, with larger lists quoted as a project. The assessment is issued under document control with its sources listed, so that when a tolerable intake is revised in the literature the compounds it affects can be found in minutes.

What you receive

  • Biological evaluation plan (BEP) to ISO 10993-1:2025, with device categorisation, exposure reasoning, endpoint-by-endpoint rationale and a justified test list
  • Toxicological risk assessment (TRA) to ISO 10993-17:2023, compound by compound, with tolerable-intake derivation, exposure estimation and margin-of-safety conclusions
  • Extractables and leachables study design to ISO 10993-18:2020+A1:2022, including analytical evaluation threshold derivation and the laboratory brief
  • Breathing-gas-pathway evaluation plan and assessment to ISO 18562-1 to -4:2024
  • Biological evaluation report (BER) consolidating the evidence and the conclusion
  • Laboratory briefs, report reviews and gap closure notes for each test commissioned
  • Change assessments for material, supplier or process changes, stating which endpoints are affected

Frameworks and editions

Applicability is device-specific. Which of these apply, and in what combination, depends on device type, intended purpose, classification and target market; the applicability assessment at the start of every engagement settles it in writing.

Frameworks and current editions cited on this page
ReferenceEdition or version citedWhere it applies
ISO 10993-1:2025Sixth edition, published 18 November 2025 (EN ISO 10993-1:2025)Biological evaluation within a risk management process; categorisation; endpoint selection; reasonably foreseeable misuse
ISO 10993-17:2023Third editionToxicological risk assessment of medical device constituents
ISO 10993-18:2020+A1:2022Second edition with Amendment 1Chemical characterisation within a risk management process; analytical evaluation threshold
ISO 10993-5:2009, -10:2021, -23:2021 and other partsCurrent editions as applicableCytotoxicity, sensitisation, irritation and the remaining endpoint-specific test methods
ISO 10993-6:2026 and ISO 10993-7:2026Published April 2026Local effects after implantation; ethylene oxide sterilisation residuals
ISO 18562-1, -2, -3 and -4:20242024 editionsBiocompatibility evaluation of breathing gas pathways in healthcare applications
ISO 14971:2019Third edition (EN ISO 14971:2019+A11:2021 for EU harmonisation)The risk management process the biological evaluation sits inside
FDA guidance, Use of ISO 10993-1Current FDA guidance on biocompatibility evaluationUS reviewer expectations where they add to the standard

What this engagement excludes

  • Laboratory testing of any kind; analytical, in-vitro or in-vivo work is performed by accredited laboratories and invoiced by them
  • Formulation or material selection advice beyond the regulatory consequences of a choice
  • Clinical evaluation; where clinical data is needed to close a biological endpoint, that is scoped separately
  • Notified-body or FDA fees

Boundary

Authentcare designs the evaluation and writes the assessment. Laboratories generate the test data. Regulators and notified bodies decide whether the evidence is sufficient.

Questions manufacturers ask

Ready to scope the work?

Bring the device description, the markets you want and whatever documentation exists. Thirty minutes is enough to know what comes first.